| Term. Label |
Description |
| 1-12 Audio In-Monitor inputs
1-6 |
Six pairs of audio inputs are each coupled to the decoder by 600 ohm to
600 ohm isolation transformers. These six audio sources are scanned for EAS alert
messages. |
| 13-14 Audio Out - 600 ohm
select |
Balanced 600 ohm continuous audio output from an operator selected monitor
input. Any channel #1 - #6. |
| 15-16 Audio Out - 8 ohm
select. |
Balanced 8 ohm continuous audio output from an operator selected monitor
input. Any channel #1 - #6. |
| 17-18 Audio Out - 600 ohm
alert |
Balanced 600 ohm audio output from the channel carrying the alert message.
This output is gated on when the alert takes place |
| 19-22 Control Out - Alert |
Two contact closure outputs can be used to signal remote control
equipment, automation equipment, or to activate a remote bell or lamp. |
| 23-24 Console Muting |
These terminals allow console muting of the panel speaker when the unit is
installed in an on/air room. |
| 25-32 Audio In/Out
Program
Lines A/B |
Eight terminals for balanced 600 ohm stereo program audio lines. Via these
inputs and outputs, the encoder interrupts the program audio to insert the alert message. |
| 33-34 Control Out - Send Alert |
Contact closure which can complete the circuit for an external relay coil
for a coaxial relay during the time the encoder is sending an alert signal. This will
allow a low impedance coaxial alert feed directly into a transmitter exciter circuit, thus
bypassing all audio processing or energizing external relays to put the alert on
additional transmitters. |
| 35-36 Control Out - EAS -
Complete |
Contact closure output to signal automation equipment that the EAS
interruption is completed. |
| 37-38 Control In - Delete Audio |
Contact closure input for deleting the 853/960 attention signal and the
audio message portion of a received alert message. The encoder will send only the FSK
(frequency shift keying) header and EOM (end of message) portions. The contact closure
would be supplied by remote switch or remote control equipment contacts. |
| 39-40 Control In - Send Alert |
Contact closure input to tell encoder to send a stored alert message now. |
| 41-42 Control In - Local |
Contact closure input to switch the encoder from automatic to manual
control. |
| 43-44 Control In - EOM |
Contact closure input to remotely send EOM (end of message). FSK code. |
| 45-46 Control In - RWT |
Contact closure input to remotely send RWT (required weekly test). FSK
header code and FSK EOM code. |
| 47-48 Control In - RMT |
Contact closure input to remotely send RMT (required monthly test). FSK
header code and dual tones. |
| 49-50 Data In/Out - RS485 |
Serial data option for future remote control equipment. |
| 51-52 |
Spare terminals for future use. |