50 or 75 ohm terminations, N or UHF sample line receptacles.
Ratio:
range - 0 - 1.999
resolution - .001
accuracy - typical .5% or better. FCC spec.; 2% for ratios from .5 to 1.0, 5% for ratios
from .2 to .5.
D.C. output for remote reading via telemetry or phone line - max. voltage; 4.5 VDC for
ratios of 1.999. Linearity .5% or better. Minimum load, 4000 ohms.
Phase:
range - 0 to +/-180 degrees
resolutions - 0.1 degrees
accuracy - typically 0.5 degrees or better. FCC Spec.; 2 degrees for ratios from .2 to .5,
1 degrees for ratios from .5 to 1.0.
D.C output for remote reading via telemetry or
phone line - max. voltage; 5 VDC for 180 degrees phase. Linearity .3% or better. Minimum
load 4000 ohms.
Phase sign - automatic display. TTL level output for remote reading.
Remote Tower Selection; - by means of external contact closures - max. contact current
60 ma. DC.
Sample Signal Range; 1.8-15 VRMS.
Power - 108-132 V., 6 Watts, 50-60 hz.
Temperature - 0-50 degree C.
Display Blanking - automatic when monitor is not being interrogated.
BCD output. Multiplexed, at TTL levels with 1 TTL load fanout. Four BCD lines, Four
Digit Select Lines, one parameter select line, one phase sign line. (Intended for use with
CMR - 1 remote controller - repeater.)
Dimension - 19" Rack mount, 5 1/4" high, 6 1/2" deep. LED readout are
1/2" high.
Common point input (amplitude readout regardless of
Ratio-Amplitude switch setting)
To order specify number of towers, number patterns, sample
line impedance, and type of connector on sample line at monitor end (type N or UHF). Also
please supply operating frequency.
Cable to interconnect remote control equipment.