Q: I keep hearing about the Common Alerting Protocol (CAP). What is it?
Q: Do I have to implement CAP?
Q: Can Gorman-Redlich help me stay compliant with CAP?
Q: Is Gorman-Redlich CAP equipment certified?
Q: Is the Gorman-Redlich CAP-DEC1 a stand-alone unit?
Q: With which equipment is Gorman-Redlich CAP equipment compatible?
Q: Is my CAP-DEC 1 and legacy EAS combination compliant with the latest FCC R&O (six-zeros and NPT)?
Q: Will my CAP-DEC1 Handle the November 2019 IPAWS security changes?

GR Equipment and Company Information
Q: Is Gorman-Redlich equipment FCC certified for use in broadcasting environments?
Q: What is the FCC ID of the Gorman-Redlich equipment?
Q: Where can I find a complete list of Gorman-Redlich products?
Q: Where can I purchase Gorman-Redlich equipment?
Q: How much does Gorman-Redlich equipment cost?
Q: Which methods of payment do you accept?
Q: How can I see Gorman-Redlich equipment in person?
Q: How can I get in touch with Gorman-Redlich Manufacturing Company?
Q: Can I hear test audio samples?
Q: How can I stay up to date with the latest Gorman-Redlich news?

Equipment Use and Troubleshooting
Q: There are two dark bars across my unit’s display screen. What is wrong with it?
Q: I received my Gorman-Redlich EAS-1 unit. What do I do now?
Q: How can I change the settings in my EAS-1 unit?
Q: Which EAS units are compatible with the Windows EASSetup software?
Q: I have downloaded the EASSetup software but I can’t extract the files. Why not?
Q: How can I keep EAS logs on my computer or CAP-DEC and avoid using a printer?
Q: How can I make sure that I have the latest CAP-DEC software?
Q: How do I configure my Gorman-Redlich alerting equipment?
Q: My CAP-DEC says “A Win32 command line email tool has stopped working.”
Q: Emails from my CAP-DEC aren’t being delivered.
Q: How do I set up my email with the new (post v2.33) software?.
Q: What is “inpout32.dll” and why is my CAP-DEC complaining about it?.
Q: How do I configure my CAP-DEC to work with my proxy server?
Q: What steps to I need to take to secure my equipment from “Zombie Invasion” messages or other unauthorized uses?
Q: Should I update to Windows 10 for my Gorman-Redlich CAP-DEC 1 unit?
Q: Should I install Windows updates my Gorman-Redlich CAP-DEC 1 unit?

Don’t see your question here? Contact us!

Q: I keep hearing about the Common Alerting Protocol(CAP). What is it?
A: CAP is an XML-based data format for exchanging public warnings and emergencies between alerting technologies which allows a warning message to be consistently disseminated simultaneously over many warning systems to many applications. CAP increases warning effectiveness and simplifies the task of activating a warning for responsible officials.
back to top

Q: Do I have to implement CAP?
A: If you are an EAS participant, yes. In May 2007, the FCC mandated that all EAS participants be able to receive alerts in CAP format within 180 days of the September 30, 2010, CAP adoption by FEMA. That deadline has been extended to 1 year from the adoption date.
back to top

Q: Can Gorman-Redlich help me stay compliant with CAP?
A: Yes! Gorman-Redlich will initially be offering a standalone CAP-to-EAS Decoder system for use with existing EAS units. In the future, we plan to offer an integrated system that combines CAP-to-EAS conversion and EAS encoder/decoder capabilities.
back to top

Q: Is Gorman-Redlich CAP equipment certified?
A: There is no certification process for Common Alerting Protocol equipment apart from FCC Part 11 certification. There does exist, however, a FEMA IPAWS Conformity Assessment Program (ICAP). The Gorman-Redlich CAP-DEC1 CAP-to-EAS decoder has undergone and passed the ICAP testing procedures and is listed in the FEMA Responder Knowledge Base (RKB) along with its Supplier’s Declaration of Conformity (SDoC).

The Gorman-Redlich CAP-DEC 1 is also FCC Part 11 certified with an FCC ID of MVZCAP-DEC1.
back to top

Q: Is the Gorman-Redlich CAP-DEC1 a stand-alone unit?
A: The Gorman-Redlich CAP-DEC1 CAP-to-EAS decoder is classified as an “intermediary device” and must be used in conjunction with certified EAS equipment such as the Gorman-Redlich EAS1 product line. For more information, please see the Understanding CAP Converters article
back to top

Q: With which equipment is Gorman-Redlich CAP equipment compatible?
A: The Gorman-Redlich CAP-DEC1 CAP-to-EAS decoder has two modes of operation:

The RS232 mode of operation is compatible with the Gorman-Redlich EAS1 line of EAS encoder-decoders and allows more rapid transmission of alerts between the CAP-DEC1 and the EAS unit, along with more detailed information.

In the AFSK mode of operation, the CAP-DEC1 emits bursts of SAME encoded AFSK data tones. These data tones may be input into any certified EAS encoder-decoder that is capable of consuming FSK data tones.

back to top

Q: Is my CAP-DEC 1 and legacy EAS combination compliant with the latest FCC R&O (six-zeros and NPT)?
A: Yes! To the best of our knowledge, the CAP-DEC 1, in conjunction with legacy EAS equipment from all major manufacturers, is compliant with the requirements set forth in the latest R&O, to include processing six-zero location codes and mandatory forwarding of the NPT event code, provided that the end-users apply the necessary messaging filters.

For more information, click here.

back to top

Q: Will my CAP-DEC1 Handle the November 2019 IPAWS security changes?
A: Yes, provided that your system and software are up to date. FCC Part 11.56(c) requires EAS participants to reject messages with invalid digital signatures. CAPDEC software v2.75 and lower do not validate digital signatures. Software v2.76.0-v2.76.2 verify that the message is correctly signed by the embedded certificate. Software v2.76.3 and above verify that the message is correctly signed by the embedded certificate as well validating the certificate trust chain.

Units with v2.76.3 or above which also have the FBCA2016 (expiring 10.28.2020)/IGCSCA1 certificates installed will correctly validate digital signatures.

Units running Win10, as well as up-to-date Win7 units, will correctly communicate with the TLS1.2 IPAWS server. Win7-based CAP-DEC1 units may have to have OS updates installed.

For update information, click here.

back to top

Q: Is Gorman-Redlich equipment FCC certified for use in broadcasting environments?
A: Yes. Gorman-Redlich is one of ten FCC certified vendors of EAS encoder/decoder units and one of only four FCC certified vendors of EAS decoder only units.
back to top

Q: What is the FCC ID of the Gorman-Redlich equipment?
A: Both the EAS-1 encoder/decoder units and the EAS-1 decoder only units have an FCC ID of MVZEAS1. CAP-DEC 1 units have an FCC ID of MVZCAP-DEC1.
back to top

Q: Where can I find a complete list of Gorman-Redlich products?
A: Our product page shows the full line of Gorman-Redlich offerings.
back to top

Q: Where can I purchase Gorman-Redlich equipment?
A: You can purchase directly through us or through one of our numerous reputable online and catalog vendors. Contact us for details.
back to top

Q: How much does Gorman-Redlich equipment cost?
A: Less than you might think! CAP and EAS compliance doesn’t have to be expensive. Contact us today to get a quote.
back to top

Q: Which methods of payment do you accept?
A: We accept payment by check, money order, PayPal and major credit cards. When purchasing through one of our distributors, contact them to determine accepted payment methods.
back to top

Q: How can I see Gorman-Redlich equipment in person?
A: We generally have representatives at major industry trade shows and conferences. Visit our shows page to see where we will be next.
back to top

Q: How can I get in touch with Gorman-Redlich Manufacturing Company?
A: Our contact information is on the contact page.
back to top

Q: Can I hear test audio samples?
A: Yes. Test audio samples are available in MP3 format on the download page.
back to top

Q: How can I stay up to date with the latest Gorman-Redlich news?
A: Sign up for the Gorman Redlich Update to receive periodical emails with the latest company news, upcoming shows and demonstrations and more.
back to top

Q: There are two dark bars across my unit’s display screen. What is wrong with it?
A: In most cases this is caused by a damaged power supply. Contact us for support.
back to top

Q: I received my Gorman-Redlich EAS-1 unit. What do I do now?
A: Plug it in! If you purchased your Gorman-Redlich unit directly from us and filled out the programming form it will already be programmed with your station’s information in it. If changes need to be made to your unit’s settings, you may either download the EASSetup software or use the front panel keypad. See the EAS-1 instruction sheet and manual for more information.
back to top

Q: How can I change the settings in my EAS-1 unit?
A: Most settings may be entered/changed via the front panel keypad. For details, see the EAS-1 manual. Settings may also be changed via the EASSetup software. For details, see software documentation.
back to top

Q: Which EAS units are compatible with the Windows EASSetup software?
A: EAS-1 units with firmware version 9.2 and above are compatible with the Windows setup software. Most firmware versions prior to 9.2 are compatible with the DOS setup software. Revision C boards will likely require hardware modification. Please contact us for details.
back to top

Q: I have downloaded the EASSetup software but I can’t extract the files. Why not?
A: The setup software is in password-protected zip files intended for use by current customers only. Contact us for details.
back to top

Q: How can I keep EAS logs on my computer or CAP-DEC and avoid using a printer?
A: Dan Bissett has created a freeware utility called EAS Monitor that achieves this functionality.
The Microsoft Windows-compatible software is free to download and use. See
this document
for details on downloading, setting up and using EAS Monitor. See this
sample configuration file for example default/recommended values.

Note that this sample configuration file will create weekly log directories directly on the computer’s C drive. To store the logs elsewhere you must create a directory (on the desktop, for instance) and copy the file path to that directory in the “file_path” element within the configuration file.
back to top

Q: How can I make sure that I have the latest CAP-DEC software?
A: First, make sure that you have signed up for the CAP Software Update Mailing List to receive notifications when new software is released. If you need a software update, use the form on this page to request the latest software update.
back to top

Q: How do I configure my Gorman-Redlich alerting equipment?
A: Gorman-Redlich EAS and Weather Radio equipment is configured using GR Setup software that is available on the downloads page. Note that there are two versions of the setup software: a DOS-based software for units with firmware v9.1 and earlier and a Windows XP/Vista/7 compatible version for units with firmware v9.2 and above.
back to top

Q: My CAP-DEC says “A Win32 command line email tool has stopped working.”
A: NOTE:  If you see this message, you have an old version of the CAP-DEC 1 software.  Software v2.33 build 4.1.2015 and above use your own 3rd party SMTP mail server to send messages.  Contact us for an update.

This error may have appeared in older software when the Java-based built in SMTP server is inaccessible. The most common cause of this is a problem with the Java installation caused by an incomplete Java update. This can happen when the user initiates a Java update and, by a quirk in the Java installer, the old Java version is removed (or corrupted) and no new version is installed.

To rectify this problem, visit this page from your unit’s browser to check if Java is installed.  If it is not, follow the on-screen prompts to do so.
back to top

Q: Emails from my CAP-DEC aren’t being delivered.

A: Is your software up to date? Software verions 2.33 and above implements a new email delivery mechanism and should alleviate nearly all delivery issues. If your software is up to date and the Send Test Email tool in the CAP-DEC 1 configuration dialog reports that the mail was sent but you did not receive it, it may have been caught up in a spam filter. Check your junk mail folders. If the Send Test Email tool reports that the mail was not sent, check your server setup information and ensure that your local network or ISP is not blocking the SMTP port.

Q: How do I set up my email with the new (post v2.33) software?

A: CAP-DEC 1 software version 2.33 and above uses a new email implementation that uses your own email provider’s server to send mail instead of the on-board SMTP server that older sofware used. As such, this software must be set up in a similar fashion to Outlok, Thunderbird, iOS mail apps, etc. with the mail server address, port, username and password.

Known good server settings include:

Gmail: [full email address][smtp.gmail.com][587][password] (must request app-specific password if 2-factor authentication is enabled)

Yahoo!: [full email address][smtp.mail.yahoo.com][587][password]

MS Live Mail: [full email address][smtp-mail.outlook.com][587][password]

GoDaddy Hosted Mail: [full email address][smtpout.secureserver.net][465][password]

1and1 Hosted Mail: [full email address][smtp.1and1.com][587][password]

We have received reports of issues configuring email functionality with Microsoft Exchange/Outlook365 servers

back to top

Q: What is “inpout32.dll” and why is my CAP-DEC complaining about it?

A: inpout32.dll is a library file required for parallel port control of the internal relay boards on CAP-DEC units equipped with such optional equipment. The CAP-DEC 1 software requires the file to be present even if the associated hardware is not. The file may be placed in the same directory as your CAP-DEC software and configuration files. If you received the software update package but do not have the inpout32.dll file, please contact Gorman-Redlich.

back to top

Q: How do I configure my CAP-DEC to work with my proxy server?
A: The URLs for the FEMA IPAWS alert feed are hard-coded into the software and are not user-editable to add proxy server information. As such, proxy servers may be used by making use of the http_proxy and https_proxy environment variables on the system. (NOTE that simply changing proxy settings through the web browser settings or other locations will not suffice)

The http_proxy and/or https_proxy environment variables may be added as described here: http://support.microsoft.com/kb/310519 (These instructions are for Windows XP but the steps are the same once you right-click on “Computer” from the start menu). See the blog post here for more information on these environment variables.

back to top

Q: What steps to I need to take to secure my equipment from “Zombie Invasion” messages or other unauthorized uses?
A: CLICK HERE to read the FCC statement regarding passwords and security of alerting equipment along with additional information about Gorman-Redlich CAP-DEC 1 security and “default passwords”.

False messages such as “Zombie Invasions” are NOT capable of being remotely generated from a proper installation of a stand-alone Gorman-Redlich EAS-1 unit, a combination of a Gorman-Redlich CAP-DEC 1 unit and a Gorman-Redlich EAS-1 unit or the combination of a Gorman-Redlich CAP-DEC 1 unit and non-network-connected “legacy” EAS equipment from other manufacturers. In such setups, the only networked equipment is the CAP-DEC 1 unit, which is not capable of originating EAS messages (rather, it is only capable of receiving CAP formatted alert messages from the specified alert feeds and translating them into EAS messages for “legacy” alert processing). Appropriate physical security measures should be taken to prevent local operators from accessing and sending messages from EAS equipment control panels.

If you do choose to create a password for your CAP-DEC 1, you must take care to remember it. If the passwords for your CAP-DEC or EAS equipment is lost, the equipment may need to be returned to Gorman-Redlich to be reset, which may result in equipment downtime or loss of data.

back to top

Q: Should I update to Windows 10 for my Gorman-Redlich CAP-DEC 1 unit?
A: Units should be kept up to date to ensure feature compatibility and optimal security, However, we do not recommend end-users perform the Windows 7-to-Windows 10 upgrade on CAP-DEC 1 units themselves. Although the software works under Windows 10, the update procedure may corrupt required files. If the update process is not properly performed, certain features may be disabled and, in some cases, the unit may cease to operate normally and require factory service.

Note that the Windows 10 operating system (OS) “upgrade” can appear as a normal Windows update as KB 3035583, including a nag screen. As any updates to the CAP-DEC system should be manually performed by your IT staff, care should be taken not to accidentally perform the OS change via update KB3035583.

If wish to have the Windows 10 update performed for you at the factory, please contact Gorman-Redlich.

back to top

Q: Should I install Windows updates my Gorman-Redlich CAP-DEC 1 unit?
A: Yes, units should be kept up to date to ensure feature compatibility and optimal security. However, updates should be performed manually rather than automatically so that a technician can observe the update process and ensure completion and successful reboot after updating. Note that for some very old versions of the CAP-DEC1 software, certain updates may corrupt the configuration or licensing files, requiring the unit to be reconfigured or have the license file reinstalled. If you have questions or problems, please contact Gorman-Redlich.